 TRUMPower
D E S C R IP T IO N
The TMP150 is a series of medical grade, class I and class II, AC/DC desktop power adapters of 132 to 150 watts output power. They are enclosed in a 94V-1 rated case with an IEC 320/C14 or IEC 320/C18 AC inlet to mate with interchangeable cord for world-wide use. All models meet CISPR 11 and FCC class B emission limits, and are designed for medical applications.
150 WATT MEDICAL POWER ADAPTERS
TMP150 SERIES
Class I, Class II
RoHS
( LV D )
F E AT U R E S
Low safety ground leakage current Optional output connectors 100% burn-in 9 0 t o 2 6 4 VAC w i d e i n p u t r a n g e O v e r v o l ta g e & o v e r c u r r e n t p r o t e c t i o n s 0.98 PFC C o m p l i a n t w i t h C E C a n d E n e r g y S ta r e f f i c i e n c y l e v e l I V r e q u i r e m e n ts No load consumption less than 0.5W Av e r a g e a c t i v e e f f i c i e n c y 8 5 % C o m p l i a n t w i t h R o H S r e q u i r e m e n ts
S a f e t y Sta n d a r d A p p r o va l s
UL 60601-1 CSA C22.2 No. 601.1
TUV EN60601-1
I N P U T S P E C I F I C AT I O N S
I n p u t v o l ta g e Input frequency Input current 90 to 264VAC 47 to 63Hz
GENERAL SPECIFICATIONS
Switching frequency 30KHz ~ 110KHz Power factor Efficiency Hold-up time Line regulation Inrush current Withstand voltage 0.98 typical at 115VAC 85% min. 15 msec minimum at 110VAC 0.5% maximum at full load 60 amps @ 115VAC or 100 amps @ 230VAC, at 25C cold start 4000VAC from input to output 1500VAC from input to ground 500VAC from output to ground 150,000 hours minimum at full load At 25C ambient, calculated per MIL-HDBK-217F Class B conducted, Class B radiated Class B conducted, Class B radiated Class B conducted, Class B radiated Harmonic distortion, Class D Line flicker ESD, 8KV air and 6KV contact Radiated immunity, 3V/m Fast transient/burst, 2KV Surge, 1KV diff, 2KV com. Conducted immunity, 3Vrms Magnetic field immunity, 3A/m Voltage dips, 30% reduction for 500ms, 60% reduction for 100ms and >95% reduction for 10ms
2.0A (rms) for 115VAC 1.0A (rms) for 230VAC Earth leakage current 90A max. @ 115VAC, 60Hz 150A max. @ 230VAC, 50Hz (Class I) E n c l o s u r e l e a k a g e c u r r e n t : 90A max. @ 264VAC, 50Hz (Class II)
OUTPUT SPECIFICATIONS
Output voltage/current Total output power Ripple and noise Overvoltage protection Overcurrent protection Temperature coefficient Transient response See rating chart See rating chart 2% peak to peak maximum Set at 112 - 140% of its nominal output voltage All outputs protected to short circuit conditions All outputs 0.04%/C maximum Maximum excursion of 4% or better on all models, recovering to 1% of final value within 500s after a 25% step load change
MTBF
EMC Performance E N 5 5 0 11 : FCC: VCCI: EN61000-3-2: EN61000-3-3: EN61000-4-2: EN61000-4-3: EN61000-4-4: EN61000-4-5: EN61000-4-6: EN61000-4-8: E N 6 1 0 0 0 - 4 - 11 :
E N V I R O N M E N TA L S P E C I F I C AT I O N S
Operating temperature Storage temperature Relative humidity Derating 0 C t o + 6 0 C - 4 0 C t o + 8 5 C 5% to 95% non-condensing Derate from 100% at +40C linearly to 50% at +60C
Tumbler Technologies + TRUMPower
3350 Scott Blvd., Bldg. 13, Santa Clara, California 95054, USA Phone: 408-988-6616 Fax: 408-988-6622 email: sales@trumpower.com Website: www.TRUMPower.com
MEDICAL GRADE
OUTPUT VOLTAGE/CURRENT RATING CHART
Output Product No. TMP150-12 TMP150-15 TMP150-19 TMP150-24 TMP150-27 TMP150-48 NOTES: Vnom. 12.0V 15.0V 19.0V 24.0V 27.0V 48.0V Imin. 0A 0A 0A 0A 0A 0A Imax. 11.0A 9.0A 7.90A 6.25A 5.56A 3.13A
TMP150 SERIES
Tol. 5% 5% 5% 5% 5% 5% Maximum Output Power 132W 135W 150W 150W 150W 150W
1. Ripple and noise : Peak-to-peak with 20MHz bandwidth and 10F tantalum capacitor in parallel with a 0.1F ceramic capacitor at rated line voltage and load ranges. 2. To order a "Class II" model with IEC320/C18 inlet, add suffix "C2", e.g. TMP150-24-C2.
MECHANICAL SPECIFICATIONS
*Add suffix "C2" when ordering "Class II" units with IEC 320/C18 inlet.
NOTES: 1. Dimensions show in inch [mm] 2. Tolerance 0.02 [0.5] maximum 3. Weight: 960 grams approx. 4. Standard output connector is a male 4-pin power DIN. Please consult TRUMPower for other connector options. 5. TMP150-12, -15, -19 output connectors are without lock. TMP150-24, -27, -48 output connectors are with lock.
PIN CHART
PIN Product No.
1
2
3
4
Shell
TMP150-12 TMP150-19 TMP150-27
TMP150-15 TMP150-24 TMP150-48
Return
Output +V
Return
Output +V
AC Ground
Tumbler Technologies + TRUMPower
3350 Scott Blvd., Bldg. 13, Santa Clara, California 95054, USA Phone: 408-988-6616 Fax: 408-988-6622 email: sales@trumpower.com Website: www.TRUMPower.com


▲Up To Search▲   

 
Price & Availability of TMP150

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X