If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
TRUMPower D E S C R IP T IO N The TMP150 is a series of medical grade, class I and class II, AC/DC desktop power adapters of 132 to 150 watts output power. They are enclosed in a 94V-1 rated case with an IEC 320/C14 or IEC 320/C18 AC inlet to mate with interchangeable cord for world-wide use. All models meet CISPR 11 and FCC class B emission limits, and are designed for medical applications. 150 WATT MEDICAL POWER ADAPTERS TMP150 SERIES Class I, Class II RoHS ( LV D ) F E AT U R E S Low safety ground leakage current Optional output connectors 100% burn-in 9 0 t o 2 6 4 VAC w i d e i n p u t r a n g e O v e r v o l ta g e & o v e r c u r r e n t p r o t e c t i o n s 0.98 PFC C o m p l i a n t w i t h C E C a n d E n e r g y S ta r e f f i c i e n c y l e v e l I V r e q u i r e m e n ts No load consumption less than 0.5W Av e r a g e a c t i v e e f f i c i e n c y 8 5 % C o m p l i a n t w i t h R o H S r e q u i r e m e n ts S a f e t y Sta n d a r d A p p r o va l s UL 60601-1 CSA C22.2 No. 601.1 TUV EN60601-1 I N P U T S P E C I F I C AT I O N S I n p u t v o l ta g e Input frequency Input current 90 to 264VAC 47 to 63Hz GENERAL SPECIFICATIONS Switching frequency 30KHz ~ 110KHz Power factor Efficiency Hold-up time Line regulation Inrush current Withstand voltage 0.98 typical at 115VAC 85% min. 15 msec minimum at 110VAC 0.5% maximum at full load 60 amps @ 115VAC or 100 amps @ 230VAC, at 25C cold start 4000VAC from input to output 1500VAC from input to ground 500VAC from output to ground 150,000 hours minimum at full load At 25C ambient, calculated per MIL-HDBK-217F Class B conducted, Class B radiated Class B conducted, Class B radiated Class B conducted, Class B radiated Harmonic distortion, Class D Line flicker ESD, 8KV air and 6KV contact Radiated immunity, 3V/m Fast transient/burst, 2KV Surge, 1KV diff, 2KV com. Conducted immunity, 3Vrms Magnetic field immunity, 3A/m Voltage dips, 30% reduction for 500ms, 60% reduction for 100ms and >95% reduction for 10ms 2.0A (rms) for 115VAC 1.0A (rms) for 230VAC Earth leakage current 90A max. @ 115VAC, 60Hz 150A max. @ 230VAC, 50Hz (Class I) E n c l o s u r e l e a k a g e c u r r e n t : 90A max. @ 264VAC, 50Hz (Class II) OUTPUT SPECIFICATIONS Output voltage/current Total output power Ripple and noise Overvoltage protection Overcurrent protection Temperature coefficient Transient response See rating chart See rating chart 2% peak to peak maximum Set at 112 - 140% of its nominal output voltage All outputs protected to short circuit conditions All outputs 0.04%/C maximum Maximum excursion of 4% or better on all models, recovering to 1% of final value within 500s after a 25% step load change MTBF EMC Performance E N 5 5 0 11 : FCC: VCCI: EN61000-3-2: EN61000-3-3: EN61000-4-2: EN61000-4-3: EN61000-4-4: EN61000-4-5: EN61000-4-6: EN61000-4-8: E N 6 1 0 0 0 - 4 - 11 : E N V I R O N M E N TA L S P E C I F I C AT I O N S Operating temperature Storage temperature Relative humidity Derating 0 C t o + 6 0 C - 4 0 C t o + 8 5 C 5% to 95% non-condensing Derate from 100% at +40C linearly to 50% at +60C Tumbler Technologies + TRUMPower 3350 Scott Blvd., Bldg. 13, Santa Clara, California 95054, USA Phone: 408-988-6616 Fax: 408-988-6622 email: sales@trumpower.com Website: www.TRUMPower.com MEDICAL GRADE OUTPUT VOLTAGE/CURRENT RATING CHART Output Product No. TMP150-12 TMP150-15 TMP150-19 TMP150-24 TMP150-27 TMP150-48 NOTES: Vnom. 12.0V 15.0V 19.0V 24.0V 27.0V 48.0V Imin. 0A 0A 0A 0A 0A 0A Imax. 11.0A 9.0A 7.90A 6.25A 5.56A 3.13A TMP150 SERIES Tol. 5% 5% 5% 5% 5% 5% Maximum Output Power 132W 135W 150W 150W 150W 150W 1. Ripple and noise : Peak-to-peak with 20MHz bandwidth and 10F tantalum capacitor in parallel with a 0.1F ceramic capacitor at rated line voltage and load ranges. 2. To order a "Class II" model with IEC320/C18 inlet, add suffix "C2", e.g. TMP150-24-C2. MECHANICAL SPECIFICATIONS *Add suffix "C2" when ordering "Class II" units with IEC 320/C18 inlet. NOTES: 1. Dimensions show in inch [mm] 2. Tolerance 0.02 [0.5] maximum 3. Weight: 960 grams approx. 4. Standard output connector is a male 4-pin power DIN. Please consult TRUMPower for other connector options. 5. TMP150-12, -15, -19 output connectors are without lock. TMP150-24, -27, -48 output connectors are with lock. PIN CHART PIN Product No. 1 2 3 4 Shell TMP150-12 TMP150-19 TMP150-27 TMP150-15 TMP150-24 TMP150-48 Return Output +V Return Output +V AC Ground Tumbler Technologies + TRUMPower 3350 Scott Blvd., Bldg. 13, Santa Clara, California 95054, USA Phone: 408-988-6616 Fax: 408-988-6622 email: sales@trumpower.com Website: www.TRUMPower.com |
Price & Availability of TMP150 |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |